
ALT Geometric foundation models (GFMs) estimate camera mo- tion and scene structure from images without requiring ex- pert parameter tuning, but either lack metric scale or rely on learned priors to infer scale, which is unobservable from monocular images alone. Inertial sensing offers a way to observe metric scale, but existing methods add inertial in- formation through a filter or factor graph, which reintro- duces bespoke parameter tuning and optimization costs that can grow with the trajectory. To bridge this gap, we present AnyVIO, a real-time, feed-forward streaming model for monocular visual-inertial odometry (VIO), which combines a streaming GFM with an inertial foundation model (IFM). Both the GFM and IFM predict the metric motion between consecutive frames, and a lightweight learned fusion head quantifies the reliability of each estimate and blends them in a single forward pass. Across nine datasets recorded from cars, legged and ground robots, and handheld and head- mounted devi

ALT Quantitative Susceptibility Mapping (QSM) provides a bulk magnetic susceptibility estimate per voxel, so contributions from paramagnetic and diamagnetic sources within the same voxel partially cancel. Susceptibility source separation methods identify these compartments by fitting a three-pool complex exponential model to multi-echo gradient-echo (GRE) data. However, conventional voxel-wise fitting with general-purpose constrained solvers requires several hours per whole-brain volume and often fails in high-susceptibility regions. We present CANON-QSM (Closed-form Alternating Newton-type Optimization for QSM), a solver that reformulates the subproblems of the three-pool model and solves them alternately via exact closed-form updates and Newton-type steps, yielding a substantial per-voxel computational speedup. Both in silico and in vivo evaluations demonstrate not only a massive reduction in reconstruction time, completing a whole-brain volume in under two minutes, but also improved acc

ALT Objective: Magnetic Resonance Elastography (MRE) is a non-invasive imaging technique for mapping biomechanical properties of in vivo tissue, including shear wave speed (SWS), but involves intrinsically slow data acquisition and an ill-posed wave inversion. Instead of relying on handcrafted image priors, we propose a data-driven approach jointly combining image reconstruction and MRE inversion for robust SWS estimation from undersampled k-space data. Methods: Our physics-informed reconstruction framework comprises two blocks: a model-based neural network (NN)-regularized reconstruction module and a phase-gradient inversion (k-MDEV) calculating SWS from the reconstructed images. Concatenating both blocks yields an end-to-end trainable method to estimate SWS directly from measured k-space data. We evaluated the method on retrospectively highly undersampled brain MRE data and compared it to a total variation (TV) minimization-based approach. We assessed the impact of end-to-end training (q

ALT Low-dose CT denoising should suppress noise while retaining the local texture of the reference image. Matching a pooled spectrum can overlook regional discrepancies, whereas pixel losses alone can favor overly smooth outputs. We propose a local band-weighted noise power spectrum loss (LBW-NPS) that compares spectral energies within overlapping Hann-tapered patches, without tissue-specific loss conditioning. Each valid patch contributes a weighted squared log-energy difference across three frequency bands, alongside an Lβ reconstruction term. We compare LBW-NPS against Lβ-only training and five auxiliary-loss baselines using the same U-Net and three seeds on DeepLesion slices with simulated low-dose acquisitions, including patch-scale ablations and lung, soft-tissue, and bone evaluations. On 220 test slices from 31 patients, LBW-NPS reduces a local spectral gap related to the loss, on 64Γ64-pixel evaluation windows, by 31.9% relative to pooled band-weighted NPS, without a statistically

ALT Blind image quality assessment (BIQA) is essential for evaluating and optimizing visual experience. Existing BIQA methods typically aggregate features from multiple backbone stages without accounting for their unequal contributions to quality prediction. Furthermore, uniformly supervising all experts may constrain their flexibility and limit the diversity of the learned quality representations. To address these issues, we present Life-IQA+, a quality representation decoding framework that combines graph convolutional network (GCN) enhanced layer interaction and flexible hierarchical expert specialization. Specifically, the layer interaction module constructs quality queries from GCN-refined deepest-stage features and uses penultimate-stage features as keys and values, thereby enabling cross-layer representation interaction via the cross-attention mechanism. Building on these representations, we further introduce a flexible hierarchical mixture-of-experts (MoE) architecture comprising a

ALT To develop and evaluate an uncertainty-aware multimodal learning framework for predicting radiation-induced xerostomia in patients receiving head-and-neck cancer radiotherapy. We developed a Bidirectional Attention-enhanced Diffusion Transformer (BA-DiT) that combines self-supervised multimodal representation learning with supervised Bayesian fine-tuning. The model integrates pretreatment CT images and three-dimensional dose distributions, focusing on bilateral parotid glands while incorporating surrounding anatomical and dosimetric information. During pretraining, bidirectional cross-attention integrates anatomical and dosimetric features, while a latent Diffusion Transformer learns joint representations through diffusion-based learning, feature reconstruction, and contrastive alignment. Supervised fine-tuning employs a Bayesian classifier to predict individualized xerostomia risk and quantify predictive uncertainty, with a learnable label-transition model accounting for potential tox

ALT BraTS-GoAT Task 3 evaluates brain-tumor segmentation across heterogeneous entities using shared ET, TC, and WT regions. We present a 3D ResidualEncoderUNet trained with quality-controlled consensus pseudo-labels, a training-only nested-region objective, and a four-expert bottleneck adapter. Five-fold ResEnc-M/L teachers gener ated predictions for 1,138 unlabeled cases; fusion, hierarchy enforcement, and confidence-and-agreement screening retained 983 for training with 1,351 annotated cases. The final five-fold ResEnc-M entry achieved mean DSC 0.834, mean NSD 0.510, and Acalc = 0.6720 on the validation server. Component effects were modest and region-dependent, with the clearest gains on ET. Source code is available at https://github.com/HeeSeung-Shin/Brats2026-Goat-HS.

ALT Self-supervised learning (SSL) is increasingly applied to scientific imaging domains, such as microscopy, where labels are scarce but noisy data is abundant. These domains exhibit significant signal-dependent noise, which can create a representational shortcut: since both augmented views derive from the same noisy image, the encoder can boost view agreement by also encoding noise patterns rather than semantic content. To enable noise-robust representation learning without knowledge of underlying noise models, we introduce Self-Aligned Noise Augmentation (SEANA), a drop-in module that generates noise-aware SSL views. SEANA learns an invertible variance-stabilizing transform (VST) from noisy data, then estimates the clean signal and resamples independent noise in learned VST space, requiring no clean targets, no dataset-specific denoiser training or use at inference, and no changes to the SSL objective or encoder. On CIFAR-10 and ImageNet-100 under synthetic Gaussian, Poisson-Gaussian, a

ALT Anomaly detection in medical images is a complex task, requiring the development of a robust model using only healthy patient data. Without access to labeled data, modern approaches typically employ self-supervised learning to obtain a model of normality. Since world models promise to build strong internal representations of their environment, we consider them as suitable candidates for the medical anomaly detection environment, namely medical investigations of healthy patients. To this end, we propose MADJEPA, a medical anomaly detector based on an enhanced multi-stage joint-embedding predictive architecture (JEPA). We design a multi-stage training pipeline to produce a robust detector: (1) image-based JEPA (I-JEPA) training aims to learn a strong representation of normal training data; (2) target encoder distillation aims to modulate over-generalization of I-JEPA representations to abnormal data; (3) pseudo-anomaly classification aims to calibrate anomaly predictions by learning a ti

ALT Deep learning systems grade prostate biopsies at the level of pathologists, but most report a grade without the glandular architecture that justifies it. This work presents a grading system built on a sparse code over the tokens of a pathology foundation model. A sparse autoencoder pretrained on biopsies is aligned with multi-reader annotations, so that 69 of its 2048 features are named after Gleason morphologies such as cribriform glands, cords, and comedonecrosis. The same code feeds a grading network, which reads all features to predict Gleason patterns and the Grade Group, while morphology maps read directly from the named features. We evaluate the system on five public datasets that include needle biopsies, tissue-microarray cores, multi-reader annotations, and three scanners. The morphology maps remain stable across alignment runs and, without retraining, detect cribriform glands in external biopsies (area under the receiver operating characteristic curve, AUROC, 0.849) and patte

ALT Images often require both denoising and interpolation, yet treating the two tasks separately is suboptimal: interpolation introduces correlated noise that complicates subsequent denoising, while denoising may remove image details useful for interpolation. In this paper, we study joint image denoising and interpolation from a mixed graph filtering perspective, where denoising is modeled using undirected graph filters and interpolation using directed graph filters. We first establish that, under mild conditions, any (pseudo-)linear denoiser and interpolator can be interpreted as solution filters of maximum a posteriori (MAP) estimation problems regularized by undirected and directed graph smoothness priors, respectively. Guided by these results, we formulate graph-based joint denoising and interpolation problems using both directed and undirected graph structures. We characterize when joint denoising/interpolation reduces to a separable pipeline and when a genuinely coupled optimization

ALT X-ray ptychography is a lensless coherent diffraction imaging technique capable of high spatial resolution, in which an image is reconstructed by solving a large-scale inverse problem from highly redundant far-field diffraction measurements acquired under overlapping illumination. Whilst the measurement redundancy created by overlapping illumination is essential for reconstruction fidelity, it leads to computational and memory demands that scale poorly with object size and target resolution when using conventional reconstruction algorithms. This work proposes a ptychographic reconstruction framework that reduces peak memory usage and time to convergence by leveraging stochastic optimisation techniques developed for large-scale machine learning. Specifically, the framework employs stochastic gradient descent with a decaying step size that progressively reduces the effect of gradient noise, referred to here as variance reduction (VR), with gradients that agree with automatic differentiat

ALT The single-particle cryo-electron microscopy imaging process is known to cause exponential decay in the amplitude and power spectra of proteins. This decay is modeled by the B factor and is currently corrected as a post-processing stage of the 3D reconstruction. As a consequence, all experimental images in the dataset are assumed to share the same B factor. In this paper, we suggest a novel approach wherein the B factor is determined and corrected as a preprocessing step to the reconstruction. We show such an approach can improve reconstruction resolution.

ALT Atomic electron tomography (AET) computationally reconstructs the 3D atomic structure of materials from a series of 2D projection measurements acquired at different tilt angles. Inspired by Gaussian splatting techniques from computer vision, we introduce an atom-centric parameterization for modeling AET samples. Instead of a conventional volumetric representation with a grid of voxels, we model the sample as a list of atoms, where each atom is a 3D Gaussian characterized by learned location, scale, and amplitude. The Gaussian model is a natural fit for atoms that allows us to easily incorporate prior information grounded in physics; we impose isotropy of atoms, a minimum interatomic distance, and realistic atomic radii. We show in simulation that our method is more robust than volumetric baselines to real-world imaging challenges, including a limited number of measurements and low electron dose. We further show that our method yields a more physically plausible reconstruction of an exp

ALT Learned image compression (LIC) papers often report BD-rate improvements of only a few percent. They are measured against VTM reference software whose version keeps changing: the claims we audit name 7 versions, 5 in 2025 papers alone. But how comparable are these numbers across papers, and what evidence should future papers give for such small gains? We introduce LIC-Audit, an analysis of 353 released rate-distortion curves from 36 repositories, and a controlled re-evaluation of eight public codec releases with 28,193 encode-decode records. We identify three problems. First, different VTM reference runs change BD-rates by up to 3.56 percentage points, and on CLIC Pro published numbers order 10 of 55 method pairs differently from a common computation; comparing codecs directly over a fixed quality range removes this dependence. Second, releases use different and mostly undocumented conventions for counting bits, computing PSNR, and padding images. Under consistent measurement, the GLIC

ALT Video compression at ultra-low bitrates presents substantial challenges in preserving perceptual quality. Although pretrained video diffusion transformers (DiTs) provide powerful generative priors, existing generative video compression (GVC) methods built on them typically rely on computationally expensive VAE decoders to reconstruct video frames. Moreover, jointly refining multiple frames to exploit the inherent spatiotemporal modeling capabilities of video DiTs introduces additional buffering delay. To address these challenges, we propose SGVC, a streaming generative video compression framework that adapts a pretrained latent video DiT into a causal pixel-space refiner. Specifically, SGVC projects decoded features from a contextual pixel codec directly into the DiT input embedding space. To bridge the representation gap between codec-derived embeddings and pretrained DiT embeddings, we introduce Embedding Alignment, which aligns the projected embeddings with input embeddings extracte

ALT Purpose: To develop and validate SWIMSS (SWInUNETR for Multiple Sclerosis white matter lesion Segmentation), a SwinUNETR-based deep learning (DL) model for reliable automated white matter (WM) lesion segmentation, in a large multicentric cohort of people with multiple sclerosis (pwMS). Methods: A real-world longitudinal dataset of 1,385 pwMS from seven Swiss clinical centers was used to train, validate, and test SWIMSS and two state-of-the-art DL architectures: UNETR and MSSegDiff. Inference results obtained with LST-AI were also compared. Preprocessed magnetization-prepared rapid acquisition gradient echo and fluid-attenuated inversion recovery MRI sequences, acquired with various MR systems and field strengths, served as model inputs. Model performance was evaluated using the Dice similarity coefficient (DSC) with 95% confidence intervals (CI). Results: SWIMSS achieved the highest performance, with a DSC of 81.37 (95% CI: 80.63-82.11), outperforming UNETR (79.06; 95% CI: 78.33-79.79)

ALT Hospitals record thousands of hours of surgical video annually, yet these archives remain difficult to search by content. Surgeons cannot readily retrieve similar operations, complications, or workflow events. Existing surgical computer vision primarily produces labels rather than retrieving relevant videos. We introduce SurgCBVR, the first benchmark for content-based video-to-video retrieval in surgery. It integrates eight public datasets across four domains-ophthalmic, laparoscopic, robotic-assisted, and colonoscopy-covering six procedure types, 679 cases, and 76,489 clips (106 hours). SurgCBVR comprises two tiers: Scene, retrieving the same operative state across cases and sites, and Workflow, retrieving and localizing phase transitions and deviations. Scene includes 74,765 clips spanning 40 classes, three temporal granularities, and three playback speeds; Workflow contains 1,724 transition clips. Fixed clip lengths and frame counts, together with phase-classifier oracle and duratio

ALT Reliable uncertainty quantification (UQ) is essential for evaluating retinal AI systems beyond classification accuracy, yet it remains unclear whether existing UQ strategies generalize across diseases, model architectures, and reliability criteria. We introduce a large-scale, multi-disease benchmark comprising over 242,000 fundus photographs from 32 datasets covering diabetic retinopathy, age-related macular degeneration, and glaucoma. We evaluate six representative UQ strategies across three Vision Transformer configurations, assessing discrimination, probabilistic calibration, selective prediction, and conformal prediction-set coverage. Our findings reveal no universally superior model or UQ strategy: methods that improve reliability in one disease or architecture may underperform in another, while improvements in discrimination, calibration, and selective prediction do not necessarily align. Notably, computationally intensive methods do not consistently outperform simple confidence

ALT Routine X-ray modalities like cone-beam computed tomography (CBCT) are optimized for high-contrast mineralized tissues, leaving soft-tissue abnormalities buried beneath photon noise and below human visual perception. Thus, detecting non-calcified pathologies requires secondary magnetic resonance imaging (MRI). We demonstrate that sub-visual radiographic signatures of soft-tissue pathology are physically preserved within routine CBCT scans and can be extracted for opportunistic screening using a targeted, physics-guided deep learning pipeline, even under extreme paired-data scarcity. Using the temporomandibular joint (TMJ) as a model system (N = 212 paired CBCT-MRI joints), we address the severe overfitting of high-capacity 3D networks through a two-stage framework. First, we employ a frozen full-grid 3D masked autoencoder (BertsWin) pre-trained on 6,550 unlabeled CBCT volumes via the GradientConductor (GCond) optimizer and an anatomy-aware objective (PhysLoss) redirecting gradient flow
