ALT A document containing the following text: QLab-Eos Networking Cheat Sheet Connect the lighting console and QLab machine via an ethernet cable. On the lighting console: In the shell, click the Network tab and make sure UDP Strings & OSC is enabled In the main console, navigate to Setup > Show Control > OSC Adjust the following settings: OSC RX: Enabled OSC UPD RX Port: 53000

ALT On the QLab machine: Open System Preferences and go to Network Click on the network with the lighting console on. Set Configure IPv4 to Manually Set the IP address to 1 higher than the lighting console’s e.g. if the LX desk is 192.168.100.101 then set the sound laptop to 192.168.100.102 Set the Subnet Mask to 255.255.0.0 Apply these settings

ALT In QLab, click the cog bottom right to open Settings, and click the Network tab. Change the Destination of Patch 3 to the IP address of the lighting console. Make sure the Port is set to 53000. Click Done. Test that this has worked by firing a network cue in QLab. The corresponding cue should fire on the lighting desk.