BHRUT Interventional Radiology (@bhr_ir) profile picture

Five member always active General Interventional Radiology team covering two hospitals - Queens and King George hospitals in East London.

Joined June 2020
Photo by BHRUT Interventional Radiology (@bhr_ir)Photo by BHRUT Interventional Radiology (@bhr_ir)Photo by BHRUT Interventional Radiology (@bhr_ir)Photo by BHRUT Interventional Radiology (@bhr_ir)Photo by BHRUT Interventional Radiology (@bhr_ir)Photo by BHRUT Interventional Radiology (@bhr_ir)Photo by BHRUT Interventional Radiology (@bhr_ir)Photo by BHRUT Interventional Radiology (@bhr_ir)Photo by BHRUT Interventional Radiology (@bhr_ir)Photo by BHRUT Interventional Radiology (@bhr_ir)
Embolization is indicated for any non salvageable accessory renal artery more than 3 mm in size.
Lessons learnt: 1. Endoanchor through two layers of stent graft is not a problem 2. Expiratory breath-hold angio for landing zone marking and graft deployment can be more accurate in these critical cases 3. 'Bent wire' technique is not useful with medtronic
Very short neck abdominal aortic aneurysm with thrombus treated successfully with Ovation Alto device. Proud to announce that we are the third hospital in the southern UK to use this device. Thanks to the Vascular surgery team, nursing staff and radiographers.
2
1
Innovative device with intriguing design. No time limits / stress to cannulate the c/l gate in time. Easy to use and deploy. Custom seal at the neck-conical, reverse conical, thrombus, calcification-anything goes (of course in limits). Ovation Alto device approved for 7 mm neck.
1
Patient with shoulder pain and focal tenderness found to have a para AC joint aneurysm- CT angio showed early filling veins too. Surprisingly, normal subclavian, thyrocervical trunk angios. Direct puncture onyx injection - good onyx spread in aneurysm and draining veins. @BPKP_IR
Post renal biopsy bleed from inferior polar renal artery. Embolized successfully with coils. Is cortical tangential approach better than radial approach in renal biopsies? @BPKP_IR
Patient post FEM-POP by pass with severe TPT and peroneal artery stenosis. Single vessel peroneal run off supplying the arch of the foot. Could not cross antegrade. Surprisingly, could not cross retrograde through a distal peroneal retrograde access too.
1
Communication with the two subintimal tracts created was made using Outback - balloon pop technique. Outback through antegrade and a balloon retrograde access. (Tip - keep a strong vacuum suction with inflation device for easy introduction of balloon without sheath)
1
Balloon punctured with outback - balloon rupture and contrast spread into adjacent vessels. Good post procedure result. (What looks like ATA is not ATA - is ATV due to a puncture site small AVF - we let the AVF stay as it will aid in keeping the treated site patent)
Emergency EVAR for ruptured aortic aneurysm on a 91-year-old. Organized and performed quickly under local anesthesia and percutaneous access, saving the patient, who was discharged uneventfully in 3 days.
1
1
7
Difficult cannulation of contralateral gate managed by snaring a 0.014 flexible wire contralaterally after introduction through an ipsilaterally placed Rim catheter.
Lucid demonstration of PAES using a low pressure inflated balloon in the popliteal artery in different foot positions.
Life saving emergency trauma intervention. A 91 year old otherwise fit gentleman with trauma, large hemoperitoneum, rib fractures and splenic laceration, hemodynamically instability, and unfit for a general anesthesia, saved by a quick emergency embolization of spleen.