M2 Electrical Installations (@m2_electrical) header
M2 Electrical Installations (@m2_electrical) profile picture

Domestic and Commercial Electrical Installation Works Carried out inc. Rewire’s, Fuse Board Replacement, Testing, Heating, Alarms, CCTV. Based in Chester

Chester, England
Joined June 2020
Photo by M2 Electrical Installations (@m2_electrical)Photo by M2 Electrical Installations (@m2_electrical)Photo by M2 Electrical Installations (@m2_electrical)Photo by M2 Electrical Installations (@m2_electrical)Photo by M2 Electrical Installations (@m2_electrical)Photo by M2 Electrical Installations (@m2_electrical)Photo by M2 Electrical Installations (@m2_electrical)Photo by M2 Electrical Installations (@m2_electrical)Photo by M2 Electrical Installations (@m2_electrical)Photo by M2 Electrical Installations (@m2_electrical)
Im trying to raise £10000 to Fund a specially adapted vehicle for a very close friend and former business partner who has MND. Check out their @JustGiving page and please donate if you can. Thank you! #MND #MotorNeuroneDisease #JustGiving#JustGiving justgiving.com/crowdfunding/…
1
1
229
MFT test kit bags…. Any recommendations??
2
1
287
Hi all! To avoid selectivity issues, what RCD protection should be fitted to protect a 16mm T+E sub main which runs through the fabric of a building (existing) feeding an RCBO loaded consumer unit? Should it be a 63A 100mA S-Type. Would this suffice? (TNC-s system) TIA
5
2
515
My thoughts were that all cables/circuits buried with the fabric of the build less than 50mm were required to be protected by 30mA but how would this get round the selectivity issues and nuisance tripping 🤷🏻‍♂️
1
1
2
252
Anyone come across these before? Customer has ordered them from Amazon. I believe they’ve come from abroad and can see a BS number on it. Thoughts??
1
1
135
Please help reach our target for someone really in need #MND #MNDassociation #Raise10K #Retweet #Share #3PeaksChallenge
Im trying to raise £10000 to Fund a specially adapted vehicle for a very close friend and former business partner who has MND. Check out their @JustGiving page and please donate if you can. Thank you! #MND #MotorNeuroneDisease #JustGiving#JustGiving justgiving.com/crowdfunding/…
114
Help! I’m having issues with my megger MFT1741+. Won’t carry out continuity tests or insulation resistance tests. Has a fault code of FUS (or FU5) fuses and contacts are fine aswell as leads. Anybody had this issue before and worked out the issue?
2
197
Evening all! Can anyone recommend a 2 channel heating/hot water time clock with 0V switching contacts? TIA 👍🏼
1
156
It’s been a while since I’ve been on here! A question to all small electrical companies…. Do you send T&C’s with your estimates? If so did you create them or doctor a template to suit your needs? If anyone can point me in the direction of a suitable template or have something I
1
1
172
Could alter, I would be most grateful! Beers in it for ya if ya ever my way 😂 🍻
112
Hello all! Anyone care to lend some advice on taking a 1st year apprentice on? Courses, Training providers, funding etc. Going round in circles on google!
5
4
506
Someone else has decided to follow me. Maybe after some tool recommendations or to discuss whether or not to earth rod a hot tub? 🤷🏻‍♂️
3
326
Been off here a couple of months or so. Thought I’d check out what everyone was upto and my time line is now full of so much crap and people retweeting total nonsense. Not sure what’s gone on here but it ain’t what it used to be
2
6
546
M2 Electrical Installations retweeted
Giveaway! Huge thanks to @OfficialNAPIT for sending these in. 25 x PRS, 25 x code breakers, 12 x on site solutions and 12 x inspection and testing! To enter follow @electrician_247 and @OfficialNAPIT Like this post Retweet #apprentice121
3
38
52
PC gone mad! Stop the world I wanna get off
1
3
967
Anyone come across these before? Used by an EV Company to tap into meter tails. Condemned and removed by eon meter monkeys. Are they to BS??
16
9
3,294
M2 Electrical Installations retweeted
The best video I’ve ever seen 🤣🤣🤣🤣🤣🤣🤣🤣🤣
319
1,277
339
8,730
1,032,256
Just installed one of these @RFSolutionsLtd wireless links on a heating system and it worked a treat. Will definitely be using again, thanks for the recommendations!
1
12
914