Have you heard of FDA's TEMPO Pilot program? Read SoftwareCPR's quick summary on the website.
softwarecpr.com/2026/08/fda-…
1
17
3-day #iec62304 and emerging #standards impacting #medicaldevice #software #training course in #boise #idaho on October 13-15, 2026 at the @BoiseState library. Learn #fda expectations for software, #cybersecurity, and #RiskManagement processes and documentation. #agile #samd #AIeD
Early Bird Registration: $995 (limited number available)
softwarecpr.com/2026/07/6230…
1
28
Fourth post on software risk analysis.
When we consider general #microprocessor failures and concerns, one generally starts with the processor operating core working outward. For example, are we certain that the basic machine instructions actually work? What about the internal memory? Then we might move outward to the external memory. Are we certain that the watchdog timer is working? Are we certain that the program image that was validated is the program image that is currently in the device. Again, our concern is once the #software is in the field – is it possible to detect failure conditions in the future in the field?
Of course, the answer is yes – we can detect many failure conditions and program startup is a very strategic time for the software to perform those self-checks. By performing the self-checks at startup, many deterioration and wear-out problems can be detected, but in the software domain, it might also be possible to detect incompatible software upgrades and potential #cyberattacks.
@SoftwareCPR highly, highly encourages more built-in self-checks! Software engineers, stand up for #quality and #safety in your devices. Educate managers as to what is necessary to ensure the #safetycase for your device. Our families are counting on you!
If you would like to discuss more, contact us at softwarecpr.com
9
Third post on software risk analysis.
We often get asked about the use of Fault Tree Analysis (#FTA) and Failure Modes and Effects Analysis (#FMEA) methods to aid with analyzing risks associated with #software. Both methods are extremely helpful in the process and I really can't imagine one being effective if not using such methodologies. However, with the proliferation of the use of more iterative and more incremental (e.g., #agile) software development lifecycles (#sdlc), it can be confusing how these methods can be employed efficiently. One rule of thumb you may find useful is that FTA is best applied during software design and software architecture activities when dealing with the high level software functionality working "top-down." FMEA (or #FMECA) on the other hand, is best applied during the software coding and unit verification activities working "bottom-up."
Continuing our thoughts of #software #risk analysis from an #fda and #iec62304 perspective, after starting with high level software functionality related to the intended use, we look next at the middle layers of the software design. Obviously good design practices such as segregation and isolation of software items can reduce all the causal pathways that one could surmise. In these layers consider algorithm errors, corruption of data, execution too slow or too fast, jumping sequence, etc. Never assume that software will just behave properly.
Particularly consider #SOUP failures or defects since we have no idea of the design quality. If SOUP is extensively used, error checking before, during, and after calls may be necessary.

ALT Rough diagram of example software architecture just so it can be illustrated that software hazards analysis starts by looking at the high level functionality software components, but then examines middle layers of the architecture as well, recognizing that errors can very likely occur in these middle layers.
"A risk assessment that includes a risk analysis, risk evaluation, risk control and a benefit-risk analysis (where applicable) should be provided for all device software. For software that is part of a system, a risk assessment should be performed on the system comprising the software and its whole hardware environment. If this information is covered in the system risk assessment documentation, this should be noted in the software documentation with reference to the particular section of the premarket submission." - 2023 #fda #software Guidance Content of Premarket Submissions for Device Software Functions. #samd #medicaldevices
#iec62304 section 7.1.1, "Identify SOFTWARE ITEMS that could contribute to a hazardous situation." Then in section 7.2.2, "Define Risk Control measures implemented in software."
The expectations of US regulations and for IEC 62304 compliance for software can be overwhelming. Software hazards analysis and risk management is certainly one of the more difficult tasks for developing medical devices containing software. This detailed analysis will require software engineers and systems engineers.
What activities should the development team perform? How do we capture the software analysis? Where do we start?
A good first step is to start with high level software functionality that relates to the intended use of the device as illustrated below. High level functionality is where we will look for specific, designed-in risk controls.

ALT Rough diagram of example software architecture just so it can be illustrated that software hazards analysis starts by looking at the high level functionality software components toward the "top" of the architecture. That high level functionality is generally what one understands the software to "do."
#iso14971 #riskmanagement must start VERY early in the #productrealization process. Even as you discuss and formalize the #intendeduse and claims for the #medicaldevice or #samd, brainstorm the #hazardoussituations associated with the intended use and capture in the preliminary hazard analysis.
18
The #medicaldevice manufacturer analyzes and considers #safety as they design the product ... and the regulator reviews.
2
Are you new to #medicaldevice development? It can help to have the right mindset. The manufacturer doesn't design products to be safe because the regulator requires it ....
1
8
Relating design input and design output to #software. There can be many layers of intermediate representations of the #software before arriving at source code or binary image. #Traceability is how we stay "true" to the #userneeds and #intendeduse. #fda #iec62304 #samd #medicaldevice
19
New AI Breast Cancer diagnostic promises earlier detection, few patients requiring chemotherapy, and financial savings.
softwarecpr.com/2022/12/prom…
1
16
“Biomechanical Energy Harvesters"- a Promising Development for Patients with DBS
softwarecpr.com/2022/11/biom…
1