Waleed R Abood (@waboodMD) header
Waleed R Abood (@waboodMD) profile picture

Epileptologist. Epilepsy fellowship director. Teaching EEG and epilepsy, building EEG learning tools. Opinions are my own.

Detroit, MI
Joined April 2023
Photo by Waleed R Abood (@waboodMD)Photo by Waleed R Abood (@waboodMD)Photo by Waleed R Abood (@waboodMD)Photo by Waleed R Abood (@waboodMD)Photo by Waleed R Abood (@waboodMD)Photo by Waleed R Abood (@waboodMD)Photo by Waleed R Abood (@waboodMD)Photo by Waleed R Abood (@waboodMD)Photo by Waleed R Abood (@waboodMD)Photo by Waleed R Abood (@waboodMD)
Longterm videoEEG case: EEG for spell capture: upper limb and trunk jerking in a patient with brain metastases. Seizure or not? Synthetic replica of the EEG: Awake, heavy muscle, movement and blink artifact. @EEGSimLab Look at the vertex: Fz-Cz and Cz-Pz show rhythmic activity that builds and slows. Then check ECG channel. #eegsimlab #EEG #Epilepsy
1
7
1
26
1,741
Suppression with GPDs!
Suppression with GPDs is not burst suppression. ACNS: a burst lasts ≥0.5 s with ≥4 phases. Shorter, or ≤3 phases, is a discharge. Burst suppression is a background. GPDs are a pattern, with their own frequency and plus modifiers. ACNS terms: eegsimlab.org
90
#cEEGWeek case from today: left delta-theta. Right sharp theta with superimposed sharp beta, unchanged an hour later. My rule: no breach rhythm on that side, with or without a lesion, plus a reported seizure, means highly likely seizure. Treatment trial. Simulated EEG #EEGSimLab
1
1
11
601
EEGSimLab is on the App store. apps.apple.com/us/app/eegsim… eegsimlab.org
EEGSimLab is now on the App Store. Practice real EEG patterns on your phone, including ACNS critical care EEG terminology. Built for students, residents and EEG readers worldwide. apps.apple.com/us/app/eegsim… #EEG #Neurology #MedEd
3
11
41
2,496
Markers (▲) show the evolving vertex rhythm. The ECG channel carries bursts of truncal EMG that begin after EEG onset and stop before it ends. Electrographic evolution plus time-locked axial muscle activation: a focal seizure from the trunk area of the motor strip.
1
2
201
Why the vertex? the trunk lies on the precentral gyrus near the midline. An MNE forward model places the scalp maximum at Cz/C2, and spread into the arm area follows.
1
1
4
169
Why the vertex? The trunk lies on the dorsal precentral gyrus near the midline. A video showing the active cortex.
20
Markers (▲) show the evolving vertex rhythm. The ECG channel carries bursts of truncal EMG that begin after EEG onset and stop before it ends. Electrographic evolution plus axial muscle activation: a focal seizure from the trunk area of the motor strip.
24
This weekend I read critical care EEGs with seizure and spike detectors enabled. You would think that makes the work easier. With the detectors currently available, it does not! I think a core problem is treating EEG as a pattern recognition problem. It is true that we spend hundreds of hours training our own neural networks to pick up the patterns, but that is only one layer in a reasoning system. That system lets us compare waveforms, drop or raise our own detection thresholds, and incorporate data from video and charts to reach a diagnosis. What we need are detectors reliable enough to take over the pattern recognition, and built to feed into how we actually reason through a record.
1
5
503
Part of EEG training is learning to ignore the sea of noise and pick up the 1% that matters. Early in training, I was overwhelmed by all the EEG data I had to review, until I learned that most is clinically irrelevant. Knowing what to ignore is as important as picking up what matters.
3
7
56
2,955
LPDs +F in an ICU patient. Which hemisphere is the source in? Image 1: average reference. Image 2: bipolar. The answer and a 3D movie of the source are in the reply. Synthetic EEG, educational use only. eegsimlab.org #EEG #MedEd
2
2
2
451
In the bipolar image: Right: Fp2-F4 down, F4-C4 flat, C4-P4 up. F4 and C4 are equally negative. Midline: Fz-Cz flat, Cz-Pz up. Fz and Cz are equally negative. Left: small deflections only. A source on the medial surface can project its field to the other side.
1
44
Answer: LEFT. The source is a patch of cortex on the left medial frontal surface (pre-SMA). It faces up and to the right. So the negative field lands on Fz, Cz, F4 and C4, and the left side goes slightly positive. The EEG looks right-sided. The source is on the left.
2
3
170
Waleed R Abood retweeted
Join us for the 5th International Conference on #AI in #Epilepsy & Neurological Disorders (February 22–24, 2027), followed by the SEEG Research Update Symposium (February 25, 2027), in Breckenridge, Colorado! aiepilepsy-neuro.com/
3
28
2,025
Aplying to epilepsy fellowship? Here is a 2-minute look at our program. youtu.be/x9zB0ZkWoSM At Wayne State University and Detroit Medical Center, fellows train at a Level 4 epilepsy center and may choose an adult or pediatric focus. Highlights: • More than 1,000 EMU admissions in 2025, including stereo-EEG • Epilepsy surgery: stereo-EEG, laser ablation, RNS and VNS • Advanced EEG: EEG source imaging and rapid-response EEG • Eleven adult and pediatric faculty, with a weekly conference and weekly didactics • No overnight call We accept two fellows each year through ERAS and NRMP. #Epilepsy #Neurology #MedicalEducation #Fellowship
3
2
7
2,883
Awake EEG. Which dipole made these spikes? Image 1: bipolar EEG. Image 2: four dipoles on the left side of the head. Reply A, B, C or D. Synthetic EEG, educational use only. #EEG #MedEd eegsimlab.org
5
11
40
2,967
Answer: B, flat, + end back. Two poles of about the same size: − in front (F3, F7), + behind (P3, P7). Bipolar: negative reversals at F3 and F7, positive reversals at P3 and P7.
99